  1. Anybody know how I set this float height on linhai 300 been blowing in gas feed pipe and setting cut off when bottom float is just above shortest jet is there easier way? Manual says float height >3 what ever that means ๐Ÿค”
  2. Hi frank I'm up and running ๐Ÿ˜€Wasnt cdi ordered new stator pick up coil while was waiting tested new regulator straight to battery terminals with an in line fuse ..no problemb old connector looked to be brittle so wired in with spade connectors when stator arrived fired straight up so not sure if was stator or short on connector learnt a lot and thanks so much for all help ๐Ÿ˜€๐Ÿ˜€๐Ÿ˜€
  3. Ah I see learning though can't thank you enough for your time top guy
  4. The wire p is pink looks like it goes ignition un plugged ignition and still had continuity on red and black with cdi plugged in so imagine that rules out ignition switch too ...getting hang of this now thanks again for help
  5. Hi frank sorry again ...just found continuity on black red wire coming from pick up coil on cdi side un plug cdi and no continuity ..short in cdi looks good bet you reckon ? ๐Ÿ˜Š
  6. The first thing to go wrong was the electronic 2x4 to 4x4 sensor which ended up buzzing as soon as I put ignition it is now unplugged could this have been a short in here and freed the cdi ?
  7. Also plugged in new regulator while starter is isolated and still popped fuse ๐Ÿ™„Red wire is showing continuity while it is attached to starter but dissconected from solenoid but the wire looks good ,there is no kill switch that's the only part that varies on diagram just a switch on front brake to let starter to operate ,starter turns over fine
  8. Just been retesting frank and original starter is now showing continuity but there are 3 what I take to be ground wires attached where one side is bolted on as per pic also getting this reading from end fuse as per pic but no continuity beep Also plugged in new regulator while starter is isolated and still popped fuse ๐Ÿ™„
  9. Could there be a short. On charging circuit causing new regulator to pop fuse not had chance to test everything with continuity yet ?
  10. Seemed to be not turning over fast enough but no difference with new replaced solenoid too ,was going to leave regulator for now as it did start and run with regulator un plugged
  11. No old one does not pop fuse but don't get any reading testing old one with volt meter new ones test out OK but blow fuse
  12. Yes still pops fuse.. But we're cheapo regulators
  13. Was just starter showing continuity which was replacement so removed and fitted original which shows no continuity engine turns over ok but still no spark have to wait for new cdi to arrive I suppose could it have been the short in starter destroyed the cdi ?
  14. Just continuity on starter now not on solenoid ...sorry about all this frank but glad of the help
  15. Un plugged and still getting continuity
  16. And from positive on starter motor showing continuity ,the on off switch is not on this bike that is the only bit of the wiring diagram that differs it does have a switch on front handle bar brake that has to be operated for starter button to operate ๐Ÿ™„ That wire is black as I ordered wrong colour hence the red insulation tape I put on it lol
  17. Hi frank ,I am getting a continuity reading between negative battery and positive solenoid with positive lead disconnected from battery is this showing a short sorry if daft question not good on electrics ๐Ÿ™ƒ
  18. Much thanks for helping with this I will try all of this when I have time ,I did try unplugging stator and bypassing ignition and plugging new regulator back in so I guess it's not stator that's nearest manual could get on a bike 2 years younger but wiring looks same.thanks again for your time
  19. Still waiting for new cdi frank but have tested out new regulator with voltmeter and is spot on but still blows main fuse immediately ,the old one does not but I tested that out and have no reading on it at all any ideas ,,does seem like a short to me
  20. @Frank Angerano will do thanks again ...will let you know Will do thanks again ...I will let you know
  21. The electronic 4 wheel drive shifter stopped working couple weeks before so bit concerned about plugging expensive cdi back in at first @Frank Angerano n
  22. Yes is in range had problemb of no spark before changed regulator though will check through wiring and ignition then go for the cdi was going to try cheap Chinese one though just to see tried 2 regulators both did same thanks again frank for input
  23. @Frank Angerano rr Will test pick up coil resistance tomorrow